How do I determine what size air conditioner I need?
To calculate the size of the air conditioner you need for a room, first, multiply the length of the room with its width. Then multiply it with 25 BTU to get the ample cooling for the room under different weather conditions. For example, if the room is 15 feet long and 12 feet wide, it comes to 180 square feet.
How much air conditioner do I need per square foot?
We need to convert BTU to tonnage. 1 ton equals 12,000 BTU. That means that, on average, we will need 0.0016 tons per square foot. To properly get the tonnage of the AC you need, you can use the AC tonnage calculator here: For example, a standard 1,500 sq ft house would need a 2.5-ton air conditioner.
How to calculate the size of an AC unit?
In order to scientifically calculate the right central air conditioner size, you can perform a Residential Load Calculation. Another way to size air conditioners is to determine the system size that is currently in place. The manufacturers do not list the air conditioner size on the unit.
How many BTU does an AC unit need?
“…an air conditioner generally needs 20 BTU for each square foot of living space.” We need to convert BTU to tonnage. 1 ton equals 12,000 BTU. That means that, on average, we will need 0.0016 tons per square foot . To properly get the tonnage of the AC you need, you can use the AC tonnage calculator here:
Why does an air conditioner unit need to be level?
Most manufacturer installation manuals specify that the unit be mounted on a level surface. When we called tech support at Goodman Manufacturing (maker of both Goodman and Amana air conditioning systems) to find out what the acceptable tolerance was for leveling a heat pump or air conditioning condenser, the answer we got was “level means level.”